Insulation Fire Resistant Cable with Copper Jacket and Durable Design

Product Details
Customization: Available
Type: Insulated
Conductor Type: Solid
Manufacturer/Factory

360° Virtual Tour

Diamond Member Since 2007

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Years of Export Experience
The export experience of the supplier is more than 10 years
Self-branded
The supplier has 14 Self-brands, check the Audit Report for more information
to see all verified strength labels (25)
  • Insulation Fire Resistant Cable with Copper Jacket and Durable Design
  • Insulation Fire Resistant Cable with Copper Jacket and Durable Design
  • Insulation Fire Resistant Cable with Copper Jacket and Durable Design
  • Insulation Fire Resistant Cable with Copper Jacket and Durable Design
  • Insulation Fire Resistant Cable with Copper Jacket and Durable Design
  • Insulation Fire Resistant Cable with Copper Jacket and Durable Design
Find Similar Products

Basic Info.

Model NO.
NBQR2408050 BTTZ
Application
Underground, Construction Cables&Wires
Conductor Material
Copper
Sheath Material
Copper
Insulation Material
Inorganic Mineral
Material Shape
Round Wire
Range of Application
Flame Retardant
Certification
ISO/CCC/RoHS
Brand
Qrunning
Jacket
Copper
Warranty
1 Year
Approximate Cable Weight
1460 Kg/Km
Standard
GB/T 13033
Cable Carrying Capacity/in Air
150A
Product Name
Rigid Fire-Resistant Cable
Transport Package
Steel Drum/Wooden Drum
Specification
3*25 mm2
Trademark
Qrunning Cable
Origin
Zhejiang, China

Product Description

Insulation Fire Resistant Cable with Copper Jacket and Durable Design
Insulation Fire Resistant Cable with Copper Jacket and Durable Design
Insulation Fire Resistant Cable with Copper Jacket and Durable Design
Insulation Fire Resistant Cable with Copper Jacket and Durable Design
Insulation Fire Resistant Cable with Copper Jacket and Durable Design
Insulation Fire Resistant Cable with Copper Jacket and Durable Design
Prodcut Name
rigid fire-resistant cable
Insulation Material
inorganic mineral
Jacket
Copper
Conductor Material
Copper
Application
Construction Cables&Wires
Model Number
BTTZ
Type
LV
Sizemm2
3*25
Warranty
1 years
Voltage
0.6/1kV
Number of Cores
3
Standard
GB/T 13033
Certification
ISO/CCC/RoHS
Insulation Fire Resistant Cable with Copper Jacket and Durable Design
Insulation Fire Resistant Cable with Copper Jacket and Durable Design
Insulation Fire Resistant Cable with Copper Jacket and Durable Design
Insulation Fire Resistant Cable with Copper Jacket and Durable Design
Insulation Fire Resistant Cable with Copper Jacket and Durable Design
Insulation Fire Resistant Cable with Copper Jacket and Durable Design
Insulation Fire Resistant Cable with Copper Jacket and Durable Design
Insulation Fire Resistant Cable with Copper Jacket and Durable Design
Insulation Fire Resistant Cable with Copper Jacket and Durable Design
Insulation Fire Resistant Cable with Copper Jacket and Durable Design
Insulation Fire Resistant Cable with Copper Jacket and Durable Design
Is your establishment a manufacturing powerhouse or a trading entity? Ningbo Qrunning Cable Co., Ltd. stands as a national high-tech enterprise, expertly devoted to the meticulous research, innovative development, robust production, and dynamic sales of superior quality wire and cable solutions. What is the duration of the warranty coverage for your products? Our exemplary warranty period for products spans a remarkable range of 1 Year to 25 years, meticulously tailored according to the specific type of electric cable and its unique application environment. Could you elaborate on your principal electric cable offerings? - High and Extra High Voltage Electric Cable: Up to an impressive 500kV. - Medium Voltage Electric Cable: Ranging from 1kV to 35kV. - Low Voltage Electric Cable: Below 1kV. - Electric Wires and Bare Conductors: Essential components in various applications. Which prestigious standards and certifications do your cables adhere to? - UL (Underwriters Laboratories): Guarantees safety and stellar performance. - IEC (International Electrotechnical Commission): Sets the benchmark for international electrical standards. - NEC (National Electrical Code): Provides authoritative guidelines for U.S. electrical installations. - RoHS (Restriction of Hazardous Substances): Ensures cables are devoid of specific hazardous materials. What are the diverse applications for your electric cables? - Power Distribution: Seamlessly transmitting electrical power from generation points to end-users. - Telecommunications: Efficiently carrying data and communication signals. - Control Systems: Connecting and orchestrating industrial machinery and automation processes. - Building Wiring: Providing reliable electrical connections within residential, commercial, and industrial edifices. What materials are predominantly utilized for your cable conductors? Predominantly, our cable conductors are crafted from high-quality copper, lauded for its outstanding conductivity and flexibility. Aluminum is also employed in scenarios where weight and cost efficiency are paramount, being both lighter and more economical than copper. How can one accurately determine the ideal cable size for a particular application? - Current Carrying Capacity: Ensuring the cable can effortlessly handle the anticipated load without overheating. - Voltage Drop: Maintaining voltage drop within acceptable constraints across the cable length. - Installation Conditions: Considering ambient temperature, installation methods, and environmental factors. - Standards and Codes: Adhering to pertinent electrical codes and standards for precise cable sizing. Is OEM/ODM service available with your company? We proudly offer OEM/ODM service and warmly invite you to share your innovative ideas with us without hesitation. Could you specify your payment terms? Our payment conditions are set at T/T 30% in advance, with the remaining balance due prior to the collection of goods, or via L/C at sight. What is the estimated delivery timeframe for your products? Typically, our delivery timeframe spans 20-30 days following the receipt of your deposit, ensuring prompt and efficient service.
Insulation Fire Resistant Cable with Copper Jacket and Durable Design

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier